Fit Testing Tab 8
2
Purpose Identify proper make/model/size Verify that the user can: –wear comfortably without frequent adjusting –inspect and identify faulty parts –properly don –perform positive / negative user seal checks –maintain a sufficient seal through a series of representative movements
3
Quantitative (QNFT) Test Aerosol (TSI Portacount) –Conc Outside / Conc Inside = FF Overall FF does not equal PF –new standard 100 & 500 –recommendations 1000 & 2000 TSI 2000 & 5000 Darrell Bevis Controlled Negative Pressure (CNP)
4
Qualitative (QLFT) Subjective –Odor –Taste –Irritation NIOSH warning
5
Appendix A, General Medical clearance prior to fit testing (e1) Training on donning Selection, most acceptable fit + and - pressure (user seal) checks Facial hair = NO TEST Worn 5 minutes prior to test with all other safety equipment that could interfere with the fit
6
Isoamyl Acetate Protocol Odor Threshold Screening –3 jars – odor free water – isoamyl acetate – separate room –must identify correct jar
7
Isoamyl Acetate Fit test protocol –clear drum liner –2 foot frame –proper cartridges –copy of exercises –paper towel –atmosphere stabilization (2 min.) –test exercises
8
Test exercises Normal breathing Deep breathing Side to Side Up and Down Talking Grimace (QNFT only) Bending over Normal breathing
9
Isoamyl Amyl Fit test protocol (continued) –smell odor TEST OVER –leave immediately –reselect –re-screening (olfactory fatigue?) –repeat fit test –break seal if and when a successful test is achieved