Download presentation
Presentation is loading. Please wait.
Published bySolomon Walters Modified over 9 years ago
1
Liquid metal flow under inhomogeneous magnetic field O. Andreev, E. Votyakov, A. Thess, Y. Kolesnikov TU Ilmenau, Germany
2
Electromagnetic Brake (EMBR) magnet system
3
Main goal 1. Smooth mean velocity profile Avoid flow instability Avoid sources of instability 2. Brake generated and introduced velocity fluctuations
4
Experimental setup y permanent magnet honeycomb Plexiglas cover blocks B z magnetic field Vives probe potential probe In- Ga -Sn outlet diffuser inlet contractor N S lxlx top view lyly side view lxlx N S 30 mm
5
Permanent magnet Channel: S = 2 10 cm L = 90 cm Coordinate system Liquid metal: GaInSn General view of test-section
6
M-shape velocity profile 0,25 0,5 -105 -75 -45 -15 45 75 105 -50 -25 0 50 0,5 Y, mm X, mm zyx BjF ~ max B B z B B z /jBV Flow 0,25 B
7
Governing parameters Reynolds number: Re=U 0 H/ Re<15000 Hartmann number: Ha=B 0 H( / ) 1/2 Ha=400 MHD interaction parameter: N=Ha 2 /ReN>40 U 0 < 35cm/s, B 0 =0.5T, H=2cm
8
Flow x=-106 mm -29 0 20 Streamwise velocity in the middle plane of channel potential velocimetry Re 4000
9
Streamwise velocity in the middle plane of channel ultrasound velocimetry Re 4000 magnet flow
10
Decay of velocity fluctuations under the external magnetic field Magnet Flow B
11
Accuracy of potential velocimetry in the region of inhomogeneous magnetic field is ? !
12
Principles of potential velocimetry from Ohm’s law streamwise velocity measurable values physical ERROR of the potential velocimetry yy xx
13
electrical current in the middle plane spanwise J y electrical current negative values of el.current positive values of el.current overestimated values of velocity under estimated values direct numerical simulation by E. Votyakov, E. Zienike
14
voltmeter flow potential difference between the side walls flow rate through the channelintegral estimation of error movable electrodes on the side walls
15
0 0.5 1 1.5 2 2.5 3 3.5 -6-5-4-3-20123456 x/H, dimensionless streamwise coordinate Re= 2716 4014 5312 6611 7909 9207 10505 11804 13102 Magnetic field overestimated values of flow rate under estimated values flow potential difference flow rate
16
X/H=0 stream wise velocity DOP2000 potential probe Comparison of ultrasound and potential velocimetry flow Re 4000
17
X/H=-3 stream wise velocity DOP2000 potential probe Comparison of ultrasound and potential velocimetry flow Re 4000 Vives probe
18
X/H=2 stream wise velocity DOP2000 potential probe Comparison of ultrasound and potential velocimetry flow Re 4000 Vives probe
19
X/H=6 stream wise velocity DOP2000 flow Re 4000 Vives probe Comparison of ultrasound and potential velocimetry potential probe
20
X/H=8 stream wise velocity DOP2000 flow Re 4000 Vives probe Comparison of ultrasound and potential velocimetry
21
Summary remarks The laboratory flow was investigated in the following range of the governing parameters: Ha = 400, Re 10. Potential probe qualitatively reproduces velocity field within the region of two magnet gaps in streamwise direction. Vives probe is strongly influenced by the external electric potential and could be applied on the distance which exceeds 5-6 gaps of magnet.
Similar presentations