Types of Buildings for Explosives Storage MA02 Slide 1
2
Types of Buildings Light structured buildings Medium wall building Heavy walled building Earth covered building Igloo Open bay, or open site Process building Container storage MA02 Slide 2
3
Light Structured Buildings MA02 Slide 3
4
Medium Walled Buildings MA02 Slide 4
5
Heavy Walled Buildings PES: Heavy Wall, reinforced roof PES: Heavy Wall, reinforced roof, but with a frangible facing wall towards an ES PES: Heavy Wall, but without a reinforced roof MA02 Slide 5
6
Earth Covered Buildings MA02 Slide 6
7
Igloos MA02 Slide 7
8
Open Bay or Site MA02 Slide 8
9
Process Buildings MA02 Slide 9
10
Container Storage MA02 Slide 10
11
Buildings: Non-Explosive Use MA02 Slide 11
12
Buildings: Vulnerable Construction Examples: Sensitive structures such as old historic, buildings Large factories Multi-storey office or apartment buildings Public buildings and structures of major value Large educational facilities Hospitals Major transport centres Major public utilities such as water, gas MA02 Slide 12
13
Design Considerations IATG 05:20 Whole Building Design Guide (WBDG) MA02 Slide 13
14
Design – Explosive Storage Examples: Easy to keep clean Access for checking and movement Access for free movement of air Fittings located to avoid fouling by MHE Electrical equipment appropriate to content Lightning protection Gangways Temperature 5°C or rises above 25°C MA02 Slide 14
15
Design – Protective Buildings - Personnel Buildings which are required to provide protection to personnel, such as process buildings and other occupied buildings, and which are inside the Internal Quantity Distance (IQD) for a PES, should be designed to resist blast loadings and penetration by fragments and debris MA02 Slide 15
16
Design – Ammunition Requiring Special Consideration Rockets and missiles HD1.1 shaped charge warheads MA02 Slide 16
17
Construction Materials IATG 05:20 Do not use flammable materials Watertight construction Fixing of equipment to walls and roofs MA02 Slide 17
18
Construction Materials Roofs Floors External & internal walls Drainage Doors Windows and other glazing Ventilation and air conditioning Heating and utilities Lifting equipment Lightening protection MA02 Slide 18
19
Electrical Requirements Categories: A (most ‘protective’) B C (standard for ammunition storage buildings) D MA02 Slide 19
20
Questions MA02 Slide 20