Download presentation
Presentation is loading. Please wait.
Published byEunice McCormick Modified over 8 years ago
1
Shui-Ming Hu (胡水明) University of Science & Technology of China (USTC) Hefei, China June 17, 2014, ISMS-UIUC Doppler broadening thermometry based on cavity ring-down spectroscopy TJ12
2
Beijing Shanghai Hongkong Where is Hefei?
3
γDγD 0.5 0.0 1.0 ν0ν0 ν Parameter cm ν0ν0 γDγD TkBkB Uncertainty0~ 10 ppb< 1 ppb?1ppm Doppler Broadening Thermometry (DBT) C. Daussy, et al., Phys. Rev. Lett. 98, 250801 (2007); C. Lemarchand et al., New J. Phys. 13, 073028 (2011). G. Casa, et al., Phys. Rev. Lett. 100, 200801 (2008); L. Moretti et al., Phys. Rev. Lett. 111, 060803 (2013)
4
Determination of Boltzmann Constant k B (CODATA2010) AGT: acoustic gas thermometry RIGT: refractive index gas thermometry JNT: Johnson noise thermometry INRIM: Istituto Nazionale di Ricerca Metrologica, Torino, Italy LNE: Laboratoire national de m´etrologie et d’essais,Trappes, France NIST: National Institute of Standards and Technology, USA NPL: National Physical Laboratory, Teddington, UK AGT k B =1.3806488(13) E-23 J/K Rel. Uncertainty ~ 1ppm
5
Uncertainty budget in DBT Moretti et al, PRL 111:060803 (2013) SNR of spectrum, 300 ppm (single scan) Pressure induced broadening effects, 200-500Pa Laser line width, 1MHz Better sensitivity? Better precision?
6
Cavity ring-down spectroscopy (CRDS) Very high sensitivity L eff ~ 10,000 km Large dynamic range I =I 0 exp(-t/τ) Timet=0 Intensity τ0τ0 τ
7
Frequency drift C 2 H 2 ro-vibrational line at 12629cm -1 C 2 H 2 60 Pa
8
Laser-Locked CRDS Ring-down Cavity Laser Peak Lock ULE-FPI Etalon Lock etalon λ/2 PZT DAQ PD v0v0 Switch EOM v 0 -f m v 0 +f m v0v0 Microwave Pan et al, Rev. Sci. Instrum. 82:103110, 2011
9
Laser frequency Precision: ~10 kHz Dynamic range: ~10 GHz Absorption coefficient Sensitivity: ~10 -11 /cm Dynamic range: >10 5 Sensitivity & Precision of LL-CRDS Freq. combs Freq. Ref. Microwave scan Gao et al, Rev. Sci. Instrum. 81:043105, 2010; Cheng et al, Opt Express, 20:9956, 2012 Pan et al, Rev. Sci. Instrum. 82:103110, 2011
10
Sun et al, Opt Express 19: 19993 (2011) Higher sensitivity Measurement with low sample pressures Better precision Scan with microwave Superior linear dynamic range
11
Temperature-Stabilized Ring-down Cavity T 1 - T 2 = 0.32(1) mK
12
AOM 1 AOM 2 MBR110 PBS Pol λ/4 Det2 Det1 Det3 BS ULE-FPI Det4 PZT Hart 5686 Heating wire ~ EOM × v0v0 v 0 -f m v 0 +f m v0v0 T controlled etalon PBS Etalon lock PZT v 0 +f m RF synthesizer GPS-disciplined Rb clock EOM
13
C 2 H 2 ~3.3Pa 100 s each scan SNR~10,000
14
Statistical uncertainty in determined line width N: number of scans
15
DBT Temperature from different line-profile models
16
USTC Dr. Cun-Feng Cheng Dr. Yu Sun Dr. An-Wen Liu Jin Wang, Yan Tan NIM Dr. JinTao Zhang Thank You for Attention! Summary CRDS allows DBT measurement at lower pressures in near-IR; Laser-locked CRDS allows spectral scan with high precision; RD cell thermo-stabilized to ±1mK@300K Statistical uncertainty <10 ppm (in line width) is feasible. To be improved A new RD cell thermo-stabilized at 273.16K; Laser with a line-width of 0.1kHz; More accurate (and sophisticated) line profile model……
Similar presentations
© 2024 SlidePlayer.com. Inc.