FPD Cable Routing LIST OF MATERIALS: PW08 Movable Counting House Truss 70 Ribbon Cables 56 Ribbon Cables 2 Reynolds HV cables HV Fan in 4 Reynolds HV cables.

Similar presentations


Presentation on theme: "FPD Cable Routing LIST OF MATERIALS: PW08 Movable Counting House Truss 70 Ribbon Cables 56 Ribbon Cables 2 Reynolds HV cables HV Fan in 4 Reynolds HV cables."— Presentation transcript:

1 FPD Cable Routing LIST OF MATERIALS: PW08 Movable Counting House Truss 70 Ribbon Cables 56 Ribbon Cables 2 Reynolds HV cables HV Fan in 4 Reynolds HV cables PMT Cables Truss 18 PMT cables 10 PMT cables Patch Pannel Patch Pannel AFE Boards Proton Side Pbar Side 8 PMT cables HV Fan out 13 RG58 HV cables HV Fan out 10 RG58 HV cables 2 Reynolds HV cables LMB Cables Patch Pannel 5 RG58 cables 2 RG58 cables 3 RG58 cables MCH 308 MCH 115 MCH 222

2 D2D2 D1D1 P2OP2O P2IP2I P2DP2D P2UP2U 4:1 split Fanout to HV 8 ch. cable P1OP1O P1IP1I P1DP1D P1UP1U 4:1 split Fanout to HV 8 ch. cable A1OA1O A1IA1I A1DA1D A1UA1U 4:1 split Fanout to HV 8 ch. cable A2OA2O A2IA2I A2DA2D A2UA2U 4:1 split Fanout to HV 8 channel cable 2:1 split Fanout to HV 8 ch. cable Fanout to HV 8 channel cable HV Power Supply mother board with 7 pods HV Power Supply mother board with 8 pods HV Power Supply mother board with 8 pods 8 HV RG58 cables3 HV RG58 cables5 HV RG58 cables FPD High Voltage Supply and Cables 3 DZERO HV Supply mother boards located at MCH M222 23 DZERO HV Pods to be installed in the 3 HV motherboards 4 DZERO HV Fanout unit located above motherboards on M222 4 DZERO HV Fanout unit located on FPD racks inside Tevatron 4 HV 8-channel cables from M222 to FPD stations - 80 to 100 m each 64 HV RG58 cables with HV BNC connectors ( see table for the diferent lengths) LIST OF MATERIALS: 8 channels used5 channels used HV 8 channel cables 2 HV RG58 cables5 HV RG58 cables Tevatron anti proton sideTevatron proton side

3 MCM1-2 PW8PW2PW3 7 PMT 112 channels AS PU2 PD1 PD2 PU1 Flat cables PU1[1:112] PU2[1:16] MCM3-4 PD1[1:32] PU2[17:112] MCM5-6 MCM7-8 PD1[33:112] AD2[1:48] AD2[49:112] AS PO2 PI1 PI2 PO1 PO1[1:64] PO1[65:112] PO2[1:80] PO2[81:112] PI 1[1:96] PI 1[97:112] PI 2[1:112] AFE 1 AS D1 D1 [1:112] MCM1-2 MCM3-4 MCM5-6 MCM7-8 AFE 2 MCM7-8 AS AI2 AI1 AO2 D2 D2 [1:112] AU2[1:16] MCM5-6 AU2[17:112] AD1[1:32] MCM3-4 MCM1-2 AD1[33:112] AS AD2 AD1 AU2 AO1 AO1[1:64] AO1[65:112] AO2[1:80] AO2[81:112] AI 1[1:96] AI 1[97:112] AI 2[1:112] AFE 4 AS AU1 AU1[1:112] MCM7-8 MCM5-6 MCM3-4 MCM1-2 AFE 3 7171 6262 5353 4444 PD2[49:112] PD2[1:48] AIAOAIAO DFE 2 ADAUADAU PUPDPUPD DFE 1 POPIPOPI DAUGHTER BOARDDAUGHTER BOARD DFE3DFE3 T R I G. M G R 3535 2626 1717 7 7 7171 6262 5353 4444 2626 1717 3535 TEVATRON LVDS Cables FPD L1 Trigger

4 FPD Cable Routing LIST OF MATERIALS: PW08 Movable Counting House Truss 70 Ribbon Cables 56 Ribbon Cables HV Fan in 2 Reynolds HV cables 13 RG58 HV cables HV Fan in 2 Reynolds HV cables (Pbar) PMT (Prot) PMT Truss 8 PMT cables 10 PMT cables HV Fan out Patch Pannel Patch Pannel HV Fan out 10 RG58 HV cables AFE Boards Proton Side Pbar Side