Download presentation
Presentation is loading. Please wait.
Published byKevin Norton Modified over 9 years ago
1
Vincent Sulkosky Massachusetts Institute of Technology Spokespeople: J.-P. Chen, A. Deur, F. Garibaldi Hall A Collaboration Meeting June 13 th, 2013 E97-110: Small Angle GDH Experimental Status Report
2
Motivation Precision measurement of the moments of spin structure functions at low Q 2, 0.02 to 0.24 GeV 2 for the neutron ( 3 He) Covered an unmeasured region of kinematics to test theoretical calculations (Chiral Perturbation theory) Complements data from experiment E94-010 covered region from 0.1 to 0.9 GeV 2 Finalizing systematic uncertainties and first publication
3
E97-110 Spin Polarizabilities
4
Experiment E97-110 Inclusive experiment: Scattering angles of 6 ◦ and 9 ◦ Polarized electron beam: Avg. P beam = 75% Pol. 3 He target (para & perp): Avg. P targ = 40% Measured polarized cross- section differences M. Amarian et al., PRL 89, 242301 (2002)
5
Work in Progress Finalized target analysis: Density and NMR/EPR polarizations (J. Singh) Target polarization uncertainties (V. Sulkosky) Elastic 3 He analysis (V. Laine) 2.1 GeV asymmetry and cross section completed Analysis of the other three elastic data sets in progress Finalize acceptance (V. Sulkosky) Fine tuning beam trip cuts for cross section and asymmetry consistency checks Radiative Corrections Preliminary work done by J. Singh Work on going by Tim Holmstrom Estimation of QE contribution to neutron results (V. Sulkosky)
6
“Final” Target Polarizations Analysis by J. Singh 6.6%
7
Run-by-Run Polarizations Significant Drop in Polarization
8
Polarization Ratios
9
Re-averaging of Polarizations Used the total errors, statistical and systematic in a weighted average of polarizations. EPR polarizations were excluded for 128 runs: 15 runs for Priapus at 6 degrees 113 runs for Priapus at 9 degrees Calib. SourcePenelope 6 degsPriapus 6 degsPriapus 9 degs Water NMR6.8%6.7% EPR-NMR3.9%4.4%4.0% EPR2.2%
10
Polarization Uncertainties When EPR is available, the averages are dominated by EPR and NMR calibrated by EPR. When EPR is unavailable, the averages are dominated by NMR calibrated by EPR and to a lesser extent NMR calibrated by water. PeriodTotal Uncertainty Penelope2.9% Priapus 6 degs w/ EPR3.0% Priapus 6 degs w/o EPR5.1% Priapus 9 degs w/ EPR2.9% Priapus 9 degs w/o EPR4.8%
11
Penelope at 6 Degrees
12
Priapus at 9 Degrees
13
Elastic Asymmetry Analysis Work by V. Laine`
14
Elastic Asymmetry Analysis Work by V. Laine` Preliminary
15
Summary Work is progressing Target polarizations and uncertainties finalized Acceptance analysis mostly completed; currently finalizing beam trip cuts and then checking cross section stability Additional work needs to go into radiative corrections: 1.Smoothing of the data completed (T. Holmstrom) 2.Elastic tail subtraction with acceptance and collimator effects included 3.Model for the two lowest energies Draft of first paper completed and internally circulated
16
Back-up slides
17
Stability of Cross Sections Problematic beam trip cutsGood beam trip cuts
18
Axial Anomaly and the LT Puzzle N. Kochelev and Y. Oh; arXiv:1103.4891v1
19
NMR Systematics 1% Reduces systematics from 8.2% to 6.6%
20
Priapus at 9 Degrees
21
4.4 GeV Drop in Polarization Significant Drop in Polarization 3.14 GeV/c
22
4.4 GeV Asymmetries 3.14 GeV/c
23
Charge Normalized Asymmetries Corrected for Charge and livetime
24
Systematic Uncertainties
25
9 o Acceptance Septum Mistuned 5-10% uncertainty Difficulty: ◦ Saturation effect is present ◦ A few settings were mistuned with the septum magnet ◦ tg -acceptance appears squeezed at the highest field settings ◦ Only tight acceptance cuts improve the issues
26
Tools for Inelastic Cross Sections Single Arm Monte-Carlo (SAMC) from A. Deur ◦ Uses John LeRose transport functions at 9º and apertures ◦ Updated septum magnet apertures with bore cooler ◦ Program complied with QFS subroutines to perform radiative corrections: internal and external ◦ Program utilizes the parameterized cross section for A> 2 from P. Bosted: https://userweb.jlab.org/~bosted/F1F209.f https://userweb.jlab.org/~bosted/F1F209.f ◦ Elastic radiative tail removed using Rosetail averaged over the solid angle acceptance of E97-110
27
3 He Cross Sections Applied very tight acceptance cuts on angles with P. Bosted’s 2009 model
28
Acceptance Cut Study Cut na4: chosen as the reference cut to compare others against
29
Summary of Cut Study Cut sc [deg] tg [mrad] tg [mrad] Y tg [cm] Pdiff [%] [%] Na19.002 88 33 44 -1.33.1 Na29.019 15 33 44 0.12.3 Na39.056 30 33 44 1.12.1 Na48.986 15 66 44 --- Na58.920 15 12 44 -1.32.0 Na68.789 15 -18,8 44 2.04.1 Na78.67 15 -12,8 44 1.32.0 Na88.987 15 -6,12 44 -4.21.5 Na98.996 15 -6,15 44 -7.12.1 Na108.994 15 66 88 -2.11.5 Na119.249 20 66 88 -1.61.8 Cross section cut sensitivity is typically less than 2%, as long as tg is kept away from the small angle acceptance side
30
Updated SAMC Code Work done by V. Laine` SAMC rewritten in C++ from Fortran Improved implementation of target collimator cuts Raster correction by calculating electron’s travel length through the cell Radiative corrections made for each material separately (previously done all at once) Default units now in meter, gram, GeV and radian instead of cm and mrad
31
Delta Acceptance E94-010 E97-110 Flat region of -acceptance is much smaller with Septum Simulation is not perfect on the falling edges
32
3 He Elastic Acceptance Delta y tg W-M
33
Kinematic Coverage
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.