1 MuTRG Channel map summary June 30, 2008 Tsutomu Mibe KEK 1

2 Octant and quadrant numbers Numbering convention of the quadrant number is different btw N and S. 2 St.3 St.2 St.1 RPC prototype St.3 St.2 St.1 1 2 3 4 5 6 7 8 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 1 2 3 4 Collision point North arm (2) South arm (1)

3 MuTr gaps, planes 3 station 1 muon plane 1 plane 2 Gap 1Gap 2Gap 3 plane 1 plane 2 plane 1 plane 2

4 MuTr cathode strips View from IR Count from left to right (North arm) Count from right to left (South arm) 4 1 2 3 4... (North arm)... 4 3 2 1 (South arm)

5 MuTr FEE chassis 5 From Nakagawa-san’s slide

6 MuTr FEE 6 Connector number Backplane channel Master Slave

7 MuTRG-ADTX chassis Slot 1 Slot 2 IN OUT IN OUT IN OUT IN OUT 12345678 ADTX Connector number ch=1-16 ch=17-32 ch=33-48ch=49-64 7

8 FEE-ADTX cable 8

9 CAMCAM COMCOM 16 15 14 13 9910 11 12 88776655 11223344 Flat cable Ch.1Ch.16 COM CAB Ch.2 Ch.3... FCI Connector shield Pseudo-chamber to ADTX cable pin arrangement Blue : signal White: GND

10 CAMCAM COMCOM 16 15 14 13 9910 11 12 88776655 11223344 FCI Connector shield FEE-ADTX cable pin arrangement Blue : GND White: Signal

11 FEE-ADTX (North Station 1) Gap number is indicated as color of the box for each connector. Strip region is indicated as color of the connector number. 11

12 FEE-ADTX (North Station 2) 12

13 FEE-ADTX (North Station 3) 13 Stereo wires were mistakenly selected in above table This slide is going to be updated.

14 FEE-ADTX (South Station 1) 14

15 FEE-ADTX (South Station 2) 15

16 FEE-ADTX (South Station 3) 16 Stereo wires were mistakenly selected in above table This slide is going to be updated.

17 Number of ADTX boards StationChassis/octBoard/octChassis/stationBoard/station North-16102440 North-2594072 North-37105680 North_total120192 South-16102440 South-2463248 South-3684864 South_total104152 Spare1156 Ground Total235400 17

18 MRG-VME 18 1 2 3 4.... 21 slot Rack power controller MuTRG-VME(1) (south arm) Coolig fan MuTRG-VME(2) (south arm) Coolig fan Optical patch Rack power controller MuTRG-VME(3) (north arm) Coolig fan MuTRG-VME(4) (north arm) Coolig fan Optical patch

19 MuTRG-MRG 19 IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 OUT

20 MuTRG-DCMIF 20 IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN-GTM OUT

21 MuTRG-LL1 21 Tile 1 Tile 2 Tile 3 Tile 4 To be confirmed with ISU group

22 DCM 22 1 2 3 4

23 What’s next Make connector map (FEE-ADTX) for all octants – A correction is neccesary for MuTr map for station 3 where stereo wires were picked. Create a strip-based map – strip-to-ADTXch relation Put into postgreSQL database 23