Presentation is loading. Please wait.

Presentation is loading. Please wait.

R 3 B CALORIMETER Large dynamical range p   Spectrometer ((2-3),<5 %  , p Total absorption(~80%, p up to 200 MeV) Reaction experiments at.

Similar presentations


Presentation on theme: "R 3 B CALORIMETER Large dynamical range p   Spectrometer ((2-3),<5 %  , p Total absorption(~80%, p up to 200 MeV) Reaction experiments at."— Presentation transcript:

1 R 3 B CALORIMETER Large dynamical range p   Spectrometer ((2-3),<5 %  E/E @1MeV) , p Total absorption(~80%, p up to 200 MeV) Reaction experiments at relativistic energies

2 Coordinator : D. Cortina R3B (D.Cortina) / EXL (J.A. Scarpaci)/ DESPEC (J.L Taín) Created in : February 2005 Goal: Find synergies between the different calorimeters in NUSTAR particular stress in the R&D and Desing phase but also common front to negociate with providers List: ~50 members, 16 Institutions, 11 countries Communication: Mailing list, Web page www.usc.es/genp/r3b, regular meetings, Videoconference NUSTAR CALORIMETER Working Group R3B: USC (Spain), LUND (Sweden), IEM (Spain), GSI (Germany), Chalmers(Sweden), Daresbury (UK), Univ. Complutense(Spain), TU Munich(Germany), TU Darmstadt(Germany), UVigo (Spain), Uni Lisboa (Portugal)

3 Characterisation of existing or new scintillation materials and photo-sensors properties.  Intrinsic energy resolution, density  Maximum light emission  hygroscopic  price !!!!  stop and measured high energy p and  (thick)‏  high granularity (for relativistic energies)

4 2. Angular distribution Kinematical considerations :  emmited by a source @ 700 MeV/nucleon 1. Doppler shift 3. Doppler broadening CALIFA The effective energy in the detectors can be up a factor 3 larger 90% of the emission is between 7-130 degrees Gamma tracking of very hig segmentation Is mandatory

5 Detection of  -rays emitted by relativistic sources Scintillator perfomaces versus semiconductor Ge detectors Ge detectors provide excelent energy resolution (below 1%).......But have low efficiency

6 R3B Cost Matrix R3B Interim MoU

7 Sharing costs and responsabilities Total CALIFA 3.2 M € (price 2005) Spanish contribution 1.2 M€ ~45 % of the estimated costs ~ 8 % of R3B + 270 k€ iToF + 500 k€ common funds

8 R&D CALIFA Working Tasks IEM  Forward part, electronics, simulations USC  General design, simulations, Barrel part UVi  Engineering design and mechanical structure

9 CALIFA Working plan

10

11

12

13

14

15


Download ppt "R 3 B CALORIMETER Large dynamical range p   Spectrometer ((2-3),<5 %  , p Total absorption(~80%, p up to 200 MeV) Reaction experiments at."

Similar presentations


Ads by Google