Download presentation
Presentation is loading. Please wait.
Published byLoreen Elliott Modified over 8 years ago
1
Liquid xenon cryogenic system at KEK
2
LXe cryogenic system at KEK Xe cylinder Recovery Bottle(3.75L) SAES Getter Monotor 0.75m 3 Tank Circulation Pump (max:20L/min) P3P3 P2P2 P1P1 m TPC PTC Heat exchanger Liquid volume ~1.5L P4P4 V13 V14 V15 V10 V12 V3V4 V11 needle V8 V9 V6V5 V7 V1V2 V21 V22 V20 V17 V16 V18 V19 V23 V24 SV PT 4 PT 1 PT 2 PT 3 T ch Heater T1T1 T2T2 T3T3 June 2008 Purification
3
Gas handling panel 0.75m3 Tank PT Cryocooler Test chamber 700W compressor LXe Cryogenic system at KEK
4
Cooling test of miniature PT Cryocooler -PTR PDC08 ( 8W at 77K : Iwatani ) -Air cooled compressor (700W at 50Hz ) -20W at 147K confirmed →24W at 165K
5
Cooling, Liquefaction, Pump circulation test PT100 50mm 10mm Foil heater Results: - 19 hrs for 1.2L liquefy by PT cryocooler only - ~0.16L/h liquefaction speed - ~2 L/min of pump circulation for purification
6
New cryogenic system for LXe experiments at KEK: - For basic investigation of LXe properties - All-round studies on impurity - Verify LXe purification technique - Technology to handle a large amount of LXe in future Summary and plan
Similar presentations