Download presentation
Presentation is loading. Please wait.
Published byPenelope Atkinson Modified over 9 years ago
1
XIS2 Calibration Status at Osaka U. 2004/03/16 Overview and current status of calibration in the soft X-ray region Energy-Pulse Height relation Energy-Resolution relation Quantum Efficiency Line Profile K. Torii (Osaka U.), XIS2 team
2
Calibration method at Osaka U. We use a (calibrated) proportional counter as an absolute reference counter Calibrate XIS-EU (Seg. C) against the reference proportional counter Calibrate XIS-FM against XIS-EU (Seg. C) Proportional counter XIS-EU (Seg. C) XIS-FM
3
Calibration of EU PDPC XIS-EU Dispersed X-ray from spectrometer
4
Calibration of FM PDFe55 XIS-FM Dispersed X-ray from spectrometer
5
The datasets (2003/12-2004/3) EU : 8s × 14000 fr. (2003/12/12-30, 2004/2/17-19) FM S0: 8s × 5262 fr. (2004/2/26-27, 2004/3/8-10) FM S1: 8s × 9225 fr. (2004/3/3-6) FM S2: 8s × 11930 fr. (2004/1/6-14, 2/7-11) FM S3: 8s × 12810 fr. (2004/1/26-2/6) FM S1, S2, S3 are complete, some additional data have to be taken for S0 and EU EU:125-126eV, FMS2:127-129eV, FMS3:128-130eV EU:2.1-2.4e-, FMS2:1.9-2.5e-, FMS3:2.2-2.5e- (Normal, grade 0)
6
PH=a ・ E + b 1/a=3.720 eV/ch b=1.38 ch Energy-PH relation (FM S2, Segment C) Si-K edge
7
Qualitatively similar results are obtained for all the sensors. S0, Seg.A, Grade0 S1, Seg.C, Grade0 Energy-PH relation (S0-A, S1-C)
8
Energy-PH Relation (FM S3-A) Fe55 で決めたゲインと~ 0.1% で一致 Qualitatively similar results are obtained for grade 0 and 02346.
9
Energy-Resolution (FM S2, Segment C) FWHM = sqrt (f 0 2 + wf ・ E) f 0 =15.2eV, wf= 0.45 Si-K edge
10
Energy-Resolution (FM S3, Segment A) Qualitatively similar results are obtained for all the sensors.
11
Q.E.: Input flux is variable … +15% C-K O-K Se-L (1.38 keV) W-M (1.77 keV) Si edge Al edge Au edge
12
Ratio of 2004/2003 EU data Se L-α(1.38 keV) W-M (1.77 keV)
13
The dispersed spectra for Seg. C, Grade 02346 Se-L C-KO-K EU1 S3(×4) S2(×16) S1(×256) S0(×1024) EU2(×64)
14
Uncorrected relative Q.E. (Seg. C, Grade 02346) S3 S2 EU2 S1 S0
15
EXAFS and XANES at Oxygen K edge FMS2, Segment 2, Grade 02346 EXAFS, XANES Carbon K Oxygen K
16
Line profile (low energy tail) Oxygen-K (0.525 keV), H.V. = 1 and 5kV The effect of applied high voltage (5 kV) is almost negligible. Tail component is significantly smaller than that for XIS 1. 1 kV 5 kV Pulse Height Counts XIS1 (H.Katayama master thesis) XIS2-S2
17
Summary Cal. Data were obtained with Fe55 and spectrometer (~0.2-3 keV). E-PH, E-Resolution relations are as expected. Low energy tail component is smaller than that for XIS1 sensors. We find that X-ray flux from the generator is variable on long timescale. This has to be taken into account before calculating QE. BPSG layer thickness does not seem to be significantly thinner for FM sensors than for EU (preliminary).
18
Line profile (low energy tail) Pulse Height Tail component is significantly smaller than that for XIS 1. Counts
19
Dispersed spectra (Q.E.) EU(1 ) EU(2 ) S0 S1 S2 S3 Energy [keV]