Download presentation
Presentation is loading. Please wait.
Published byEdward Beasley Modified over 9 years ago
1
MAIN LINAC CRYOMODULE DESIGN REVIEW INPUT COUPLER September 5, 2012V. Veshcherevich
2
September 5, 2012 Bellows Air Cooling Waveguide Flange Cold Ceramic Window Instrumentation Port Pump Port 40K Flange 5K Intercept Cavity Flange (2K) Cavity Flange (2K) Antenna (Solid Copper) Antenna (Solid Copper) Warm Ceramic Window 300K Flange Most of the Parts: 316 Stainless Steel with 5 m Copper Coating 2MLC Design Review INPUT COUPLER 40K He Gas Cooling 40K He Gas Cooling
3
September 5, 20123MLC Design Review INPUT COUPLER Operating frequency1.3 GHz Maximum power (CW)5 kW Q ext (fixed)6.5×10 7 Cold coaxial line impedance 70 Ohm Warm coaxial line impedance 46 Ohm Cold coax line outer diameter 40 mm Warm coax line outer diameter 62 mm Main Parameters of the Coupler
4
September 5, 20124MLC Design Review Heat Load on Cryogenics Static Heat Load Dynamic Heat Load Full Heat Load To 2 K0.05 W0.06 W0.11 W To 5 K0.64 W0.32 W0.96 W To 40 K3.78 W5.94 W9.72 W INPUT COUPLER
5
September 5, 20125MLC Design Review INPUT COUPLER Parts of Coupler
6
September 5, 20126MLC Design Review INPUT COUPLER Cryomodule with Coupler VAT Valve Coupler Port Ion Pump Cold Cathode Gauge
Similar presentations
© 2025 SlidePlayer.com. Inc.
All rights reserved.