Download presentation
Presentation is loading. Please wait.
Published byJohnathan Mason Modified over 9 years ago
1
ESS Cryogenic Distribution System for the Elliptical Linac CDS Heat Loads Calculations Preliminary Design Review Meeting. 20 May 2015. ESS. Lund. Sweden J. Polinski. J. Skrzypacz. P. Jaszak
2
Heat paths to the CDS process lines Fixing supports Vacuum barrier in the Jumper Connections Sliding supports Thermal Insulation - MLI Croygenic Valves
3
Fixed Support Heat Transfer CTL – 14 supports CDL – 30 supports CDLVLPHe supplyTS supplyTS return Heat [W]0.770.360.1322.2 CTLVLPHe supplyTS supplyTS return Heat [W]1.220.30.122.5
4
Vacuum Barrier Heat Transfer VLPHe supplyTS supplyTS return Heat [W]0.15460.0450.03830.136 CTL – 0 VB CDL – 30 VB
5
Sliding Support Heat Transfer CTLVLPHe supplyTS supplyTS return TS Heat [W]0.140.001-0.0530.0121.78 CTL – 27 CDL – (4×30)=120
6
Multi Layer Insulation He Supply Line – 50-4K. 10 layers VLP Line – 50-4K.10 layers TS Supply Line – 50-40K. 10 layers TS Return Line – no MLI. TS Return = TS Thermal Shield (TS) –300-50K. 30 ÷ 40 layers Temp. range300-50 K50-40 K50-4K Heat [W/m 2 ]1.30.010.1
7
Cryogenic Valves Heat Transfer – after WEKA AG catalogue Valve NameLocation Valve size Heat 300 – 20K W Heat 300 – 4K W CV03He Supply LineDN 10NA0.33 CV04VLP LineDN 50NA2.6 CV06VLP LineDN 15NA0.47 CV60TS Supply LineDN 60.19NA CV61TS Return LineDN 60.19NA CV63TS Return LineDN 60.19NA Total number of the valves – 30 of each type
8
Heat Loads to CTL Size OD mm Length m Area m 2 MLI 300-40K W/m 2 MLI 50-40K W/m 2 MLI 40-4K W/m 2 Sliding Supports W Fixing Supports W He supply lineDN6576.16415.3001.530.0274.2 VLP lineDN2502736454.9005.493.7817.08 TS Supply LineDN5060.36412.100.1210-1.4311.4 TS Return LineDN5060.36412.1=TS000.324315 Thermal ShieldNA4756495.51240048.060 Heat Total to CTL W Heat Limit W Prc. of Limit % He supply line5.7510.355.9 VLP line26.3431.882.8 TS Supply Line0.095.51.64 TS Return Line487.54450108.3
9
Heat Loads to CDL Size OD mm Length m Area m 2 MLI 300-40K W/m 2 MLI 50- 40K W/m 2 MLI 40- 4K W/m 2 Sliding Supports W Fixing Supports W He supply line DN6576.125661.2006.120.1210.8 VLP line DN250273256176.20017.616.823.1 TS Supply Line DN5060.325648.4900.4850-6.363.9 TS Return Line DN5060.325648.49=TS001.44666.0 Thermal Shield NA475256382496.600213.60 Size ODLengthArea MLI 300- 40K MLI 50- 40K MLI 40- 4K Sliding Supports Vac. Barrier Valves mmmm2W/m2 WWW He supply lineDN1017.153.980.2140021.4E-30.031.359.9 VLP lineDN5060.33.670.695006.96E-34.24.6492.1 TS Supply LineDN813.73.330.14301.4E-30-1.591.155.7 TS Return LineDN813.7NA =TS000.364.0811.4 Thermal ShieldNA9240.822.383.100NA Main Headers Branch Headers
10
Heat Loads to CDL Main Headers W Branch Headers W Heat Total to CDL W Heat Limit W Prc. of Limit % He supply line17.0411.328.3471.139.86 VLP line57.52101158.5203.877.78 TS Supply Line-1.975.263.28537.28.83 TS Return Line137718.941396183176.27
11
Heat Loads to CDS Heat Total to CTL W Heat Total to CDL W Heat Total W Heat Limit W Prc. of Limit % He supply line5.7528.3434.0981.441.9 VLP line26.34158.5184.9235.678.5 TS Supply Line0.093.2853.37542.77.9 TS Return Line487.5413961884228182.6